Home >> Projects >> Municipal application

Municipal application

Municipal application

    The induction lighting is a new type of lamp with high lumen efficiency and long life time
     which meet the global low carbon emission and green lighting requirements. It saves a lot of energy and reduces the maintenance cost significantly. The applications show that the same visual effect is reached when the metal halide lamp or sodium lamp is replaced with lower-watt induction lamp, which result in high power factor, the reduced cable size, the reduced initial investment of the power line and the reduced energy.The induction lighting has been used in many areas such as the surrounding area of Beijing Olympic Stadiums,T3 Terminal Building of Beijing Airport, Shanghai Bund Tunnel, Shanghai Volkswagon, Shanghai General Motor, Zhengzhou Yutong Auto, Gree Electrical Appliance, workshops, garage, street and roadway, etc.
    A large number of applications show that the induction lighting can save more than 40% of energy
     than that of metal halide or sodium lighting system.The induction system and fixture are designed
    and manufactured in the same company for high reliability and performance.

Advantages of induction lighting

  • No electrode with 100k hours operation, maintance-free, suitable for the high ceiling workshop, sport stadium, roadway and building where are difficult to access;

  • No flash with soft and gentle lighting, CRI more than 80 with good visual effect

  • High luminance and low lamp depreciation to meet the lighting requirement within the life time;

  • Instant on and instant hot restrike(VS long delay time of start and restrike of HID lamps)

  • Driven by the eletronic ballast with high power factor and low current to reduce the capacity of power distribution equipment(transformer and cable)

  • The dimmable range from 40% to 100% fo rating to work with many intelligent dimmer or control systems without compromising lighting effiency and color rendering index to save energy

  • Unique advantages of induction lighting in the following applications 

      Difficult accessible area
      For example, the tunnel lighting requires no maintenance and long lifetime.The relamping has to take place once one or two years for the sodium lamp while the induction lighting does not need relamping in 10 years.The closing of the tunnel

      for the maintenance purpose is complicated and troublesome.The induction lighting

      is good for manufacturing workshop, roadway, high pole, refrigerator room etc where are difficult to access.

      High performance lighting requirement area
       
      The foodstuff, automobile assembly, machining, mechanical fabrication, electronic

      and textile industries requires high color rendering index and no dizzy lighting.

      The induction lighting is good for workshop, sports stadium, supermarket and

      public area.

      Longtime operation requirement and frequent on & off area

      Instant hot restrike requirement area

      Community, park, home, architecture
      The low-watt induction lighting are good for these area. 

      Agriculture and hydroponics
      Full spectrum induction lighting is good for the vegetable and flower.The low lamp temperature reduces the lighting distance between the lamp and crop with the same
      or better luminance while saving energy VS HID lamp. 

      Classroom and library
      The induction lighting is good for eyesight protection due to the features of
      non flash, soft and gentle lighting.

      Solar lighting
      The induction lighting with DC power design works with the solar panel in the street and other public lighting area to save power supply cable and energy and reduce carbon emission.

      High-speed rotation machine workshop
      The features of induction lighting with high CRI, high lumen, no shadow, no glare
      and no flickering provide a comfortable working environment for human eyes
      especially in high-speed rotating machine workshop.

      Livestock and poultry farm
      Shadowless and no flickering makes the induction lighting suitable for the farm.
    Comparison for Induction Lamp and Traditional Lighting Source

    Light source

    Color

    Temperature(K)

    CRI

    Lighting

     efficiency (Lm/W)

    Average

    lifetime (h)

    Incandescent lamp

    2800

    100

    15

    1,000

    Quartz-Halogen Lamp

    3000

    100

    15

    2,000-3,000

    Normal fluorescent lamp

    Full range

    70

    70

    8,000

    Tri-phosphor fluorescent lamp

    Full range

    80-98

    96

    10,000

    High pressure MV lamp

    3300/4300

    45

    50

    3,000-6,000

    LPS

    1700

    44

    150-200

    14,000-28,000

    HPS

    2200

    23

    90-120

    12,000-24,000

    MH

    3000/4500/5600

    65-90

    75-95

    6,000-20,000

    Induction lamp

    Full range

    ≥80

    70-90

    100,000

    Comparison Between Induction Lamp and HID lamp

    Items

    Induction lamp

    MH lamp

    HPS lamp

    Average lifespan

    100K hours

    15K hours

    24K hours

    Average operating lifespan

    >60K hours

    Approx 8K hours

    Approx 10K hours

    Gear

    Electronic

    Magnetic ballast, igniter, capacitor (Too many parts resulting in inconvenient maintenance and assembly)

    Magnetic ballast, igniter, capacitor (Too many parts resulting in inconvenient maintenance and assembly)

    Dimmable function

    Low pressure discharge lamp; The  lighting efficiency, color temperature and color rendering index do not change or change very little.

    High pressure discharge lamp; The lighting efficiency, color temperature, the color rendering index are based on a certain temperature and these performances change a lot when the arc discharge condition changes at dimming condition.

    High pressure discharge lamp; The lighting efficiency, color temperature, the color rendering index are based on a certain temperature and these performances change a lot when the arc discharge condition changes at dimming condition.

    System wattage

    400W: System wattage at 420w
    100w: System wattage at 105w

    400W: System wattage at 445w.
    100W: System wattage at 115w.

    400W: System wattage at 445w.
    100W: System wattage at 115w.

    Starting current

    400W: ≤1.95A; 100W: ≤0.49A
    The low starting current reduces size of the cable and the power distribution cubicle.

    400W: ≤5.7A; 100W: ≤2.4A

    400W: ≤7.5A; 100W: ≤2.4A

    Power factor

    ≥0.98

    0.43 (≥0.85 after power factor correction)

    0.43 (≥0.85 after power factor correction)

    System lighting efficiency

    >80 lm/w

    >80 lm/w

    >85 lm/w

    CRI (Color rendering index)

    >80 (Easy and clear identification for vehicles and pedestrians)

    60-70

    23

    Color temperature

    2700K to 6500K

    4000K

    2200K

    Flash effect

    No flash and dizzy light

    Obvious flash and dizzy light

    Obvious flash and dizzy light

    Hot restart performance

    Instant on

    10 to 15 minutes (Negative to the lamp life at hot restart)

    5-10 minutes (Negative to the lamp life at hot restart)

    Output wattage

    Constant output wattage

    Variation as per voltage fluctuation

    Variation as per voltage fluctuation

    Voltage VS lamp power

    ±20%/ ±3%

    ±10%/±20%

    ±10%/±20%

     

    Copyright © 2006-2012, Registered trademark , Jieming Optoelectronic Co., Ltd. All Rights Reserved